Pipe Calculation

 

This page is to help you determine what you need for a complete flue system.

 A complete flue system requires;

 
3" double wall flue pipes ( 22.5" of usable flue pipe, 1.5" loss )


An exit kit to exit the flue pipe ( 23" of usable flue pipe, 1" loss )

Enough 5" insulated pipe to insulate the 3" as it goes through the ceiling, roof and to outside.

Keep in mind that the exit kit comes with either a 24" section of 5" pipe or 2 x 12" 5" pipes. They do NOT come with any 3" pipe.

 The amount of pipe needed depends on the height the stove is installed, the distance needed to pass the highest point by one foot and the placement of the stove itself.

Please see below how to calculate the pipe for a flat, round and pitched roof.

  • Van/Flat Roof

    3" Double Wall Flue Pipe
    1.  A - B + 12" = Total length of 3" double wall flue pipe in inches.
    2. Total length of 3" double wall flue pipe in inches divided by 22.5 = # of 24" long sections.
     5" Insulated Pipe
    1. 12" + 2" + C = Total length of 5" insulated pipe in inches.
    2. Total length of 5" insulated pipe in inches divided by 23" = # of 24" long sections

    ( 12" sections available as well)

  • Skoolie/Rounded Roof

    3" Double Wall Flue Pipe
    1.  A - B + 12" = Total length of 3" double wall flue pipe in inches.
    2. Total length of 3" double wall flue pipe in inches divided by 22.5 = # of 24" long sections.
     5" Insulated Pipe
    1. 12" + 2" + C = Total length of 5" insulated pipe in inches.
    2. Total length of 5" insulated pipe in inches divided by 23" = # of 24" long sections

    ( 12" sections available as well)

  • Pitched Roof

    3" Double Wall Flue Pipe
    1.  A - B + 12" = Total length of 3" double wall flue pipe in inches.
    2. Total length of 3" double wall flue pipe in inches divided by 22.5 = # of 24" long sections.
     5" Insulated Pipe
    1. 12" + 2" + C = Total length of 5" insulated pipe in inches.
    2. Total length of 5" insulated pipe in inches divided by 23" = # of 24" long sections

    ( 12" sections available as well)

1 of 3

Differences Between Installation Heights

THE PIPE BEGINS WHERE THE TOP OF THE STOVE IS LOCATED.

THE STOVE WILL HEAT BELOW IT. THIS IS JUST TO SHOW THE DIFFERENCE THAT THE INSTALLATION HEIGHT HAS ON EFFICIENCY.